As the demand for servers and IT infrastructure continues to grow, one of the main challenges is cooling servers and data center environments. Efficient data center cooling improves server performance and enhances overall operational processes. For this reason, various cooling methods have been developed over the years.

Why Is Data Center Cooling Important?

Data centers contain a large number of servers used for various purposes. One thing these servers have in common is their heavy workload, which causes their processors and chips to generate a significant amount of heat.

To better understand this, think about your laptop or personal computer. When it is pushed beyond its normal workload, notice how intensely the system fan operates and how much heat the device generates.

Since servers are often referred to as supercomputers, they also produce a great deal of heat. If this heat is not removed, server performance will gradually decline, and the servers will no longer be able to operate as efficiently as before. Therefore, an environment such as a data center, which houses many servers, must also have a suitable cooling system.

Today, cooling systems have become one of the main criteria businesses consider when choosing a data center. Given the importance of cooling systems to server performance, many cooling methods have been developed for data centers. Some have proven practical, while others have not. However, one thing is clear: as the use of servers has increased over time, so has the need for new cooling technologies.

Data Center Cooling Methods

Several methods are available for cooling data centers, which we will examine in this section.

  • Air Cooling

This cooling method uses fans, air-conditioning systems, vents, and other equipment to create airflow. Air cooling removes the hot air generated inside the data center and replaces it with fresh, cool air. It is one of the most widely used cooling methods and is found in many data centers.

In the past, air cooling was sufficient for many requirements. Today, however, workloads have increased in both volume and intensity, meaning this method may no longer be suitable or efficient enough for every data center.

Air cooling is generally used for racks with a power density of less than 20 kW.

  • Liquid Cooling

In direct liquid cooling, coolant is delivered through a network of pipes to heat-generating components such as CPUs and GPUs. As the liquid passes through components such as cold plates, it absorbs heat. Once heated, it returns to the cooling loop to be cooled and circulated again.

In this method, the liquid comes into direct contact with the chips or their cooling components, but the entire server is not submerged in liquid.

  • Immersion Cooling

In this method, the entire server is submerged in a liquid. You might assume that this would damage the server while removing the heat, but that is not the case. In immersion cooling, the server is placed in a non-conductive liquid, so no damage is caused to its components.

The liquid absorbs the generated heat and prevents the server from overheating. This method is so effective that extremely high-density equipment can be deployed in facilities originally designed for low or medium power densities.

Immersion cooling can be used for virtually any type of server and workload.

  • Evaporative Cooling

Since air cooling alone can no longer meet the requirements of many data centers, while replacing the entire cooling system can be extremely expensive, evaporative cooling may be the best option for these facilities.

Fans bring outside air into the data center for cooling. Before this air reaches the equipment, water evaporation removes heat from it and lowers its temperature.

  • Free Cooling

Free cooling is a method that uses available natural resources to lower the temperature of a data center when environmental conditions are suitable, reducing the need for conventional cooling equipment to operate continuously. In this method, outside air or naturally cool water sources can play an important role in transferring heat.

Technologies such as economizers, indirect air-side cooling, heat wheels, and plate heat exchangers can be used to implement this cooling system.

Whether this method can be used depends on the climate and microclimate of the data center’s location. Therefore, the environmental conditions of the site must be carefully assessed before choosing it. When conditions are suitable, free cooling can reduce energy consumption and carbon emissions. It can be particularly effective for data centers supporting demanding workloads such as AI and high-performance computing (HPC).

Global Infrastructure

Deploy Your VPS in Leading Data Centers

Choose from multiple global locations and launch a powerful virtual server with high-speed connectivity, reliable infrastructure, and flexible resources.

Buy VPS

Data Center Cooling Trends and the Future

One of the most important considerations in data center cooling is minimizing its environmental impact. Some existing cooling methods have proven effective and can continue to be widely used. However, the methods likely to become more common in the future offer greater environmental benefits and more effective ways to manage waste heat. These include:

  • Adaptive Cooling: In this method, artificial intelligence adjusts the cooling level based on the current condition and workload of the servers. This prevents excessive cooling and unnecessary energy consumption.
  • Edge Data Centers: The growing use of edge data centers allows data to be processed closer to users. These facilities can adopt newer cooling methods suited to their specific conditions.
  • Sustainable Energy: Using solar and wind energy alongside batteries and energy storage systems can help data centers reduce their energy consumption and carbon footprint.

Which Major Data Centers Use Liquid Cooling?

Major data center operators such as Google, Amazon, and Hetzner relied on air cooling for many years. Their cooling systems did not change significantly during this period, although some also introduced evaporative cooling. However, because these systems can be expensive to install and may create environmental concerns, particularly regarding water consumption and its return to the natural environment, they are not used everywhere.

Today, there is not much detailed data or information available about the cooling methods used in AI data centers. However, the infrastructure supporting platforms such as OpenAI, Claude, and Gemini must use liquid-cooling technologies, at least for servers handling extremely demanding workloads.

In 2018, Microsoft also placed a sealed, container-sized data center on the seabed to test the idea of building data centers underwater. Since seawater is electrically conductive, the server equipment had no direct contact with it and was protected inside a watertight enclosure. The relatively low and stable temperature of the surrounding seawater helped cool the servers.

These servers operated underwater for approximately two years. Despite the project’s significant potential to reduce server construction and cooling costs, no company or data center operator has since adopted this approach on a large scale.

Building data centers underwater may negatively affect marine life and could disrupt aquatic ecosystems over the long term.

Finally: How does adaptive cooling improve data center efficiency?

Adaptive cooling uses artificial intelligence and real-time data to continuously adjust cooling levels based on server workloads and environmental conditions. By providing cooling only where and when it is needed, it can prevent excessive cooling, reduce energy consumption, and improve the overall efficiency of the data center.

FAQ

1. Can immersion cooling be used for all types of servers?

Immersion cooling can be used for a wide range of servers and workloads, but not all server hardware is automatically compatible with this method. The components must be suitable for immersion in a non-conductive dielectric coolant, and factors such as hardware compatibility, maintenance requirements, and facility design must also be considered.

2. Does liquid cooling use less energy than air cooling?

In many cases, liquid cooling can consume less energy than air cooling because liquids transfer heat more efficiently than air. This means cooling systems may require less energy to remove heat from high-density servers. However, the actual energy savings depend on the cooling system design, server workload, and data center infrastructure.